1. Scope
1.1 This test method covers the determination of the melting point (cooling curve) of petroleum wax. It is unsuitable for waxes of the petrolatum group, microcrystalline waxes, or blends of such waxes with paraffin wax or scale wax. Note 1For additional methods used for testing petroleum waxes, see Test Method D 127 and Test Method D 938. Results may differ, depending on the method used. For pharmaceutical petrolatum, Test Method D 127 usually is used.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
D127 Test Method for Drop Melting Point of Petroleum Wax, Including Petrolatum
D6299 Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance
D938 Test Method for Congealing Point of Petroleum Waxes, Including Petrolatum
E1 Specification for ASTM Liquid-in-Glass Thermometers
Index Terms
cooling curve; melting point; petroleum wax; wax; ICS Number Code 75.140; 75.140
Citing ASTM Standards