Simple Extraction of Sulfite and Sulfate in Cogeneration Plant Circulating Fluidized Bed Fly Ash for Ion Chromatographic Analysis
Cowen, WF Chemicals Environmental Technology Center, Air Products and Chemicals, Inc., Allentown, PA
(Received 9
September 2004; accepted 19
November 2004)
JOURNAL JAI
Abstract
A simple method is described for analyses of sulfite and sulfate, in cogeneration plant fly ash/bottom ash from a coal-fired circulating fluidized bed (CFB) steam-electricity cogeneration process. Ash is shaken for 3 h (room temperature) in 3 mM disodium EDTA solution, and then the filtrate is analyzed by ion chromatography/suppressed conductivity. The EDTA slows the rate of metal ioncatalyzed sulfite oxidation by dissolved oxygen without using formaldehyde preservative. Sulfite standards in EDTA solution were stable for up to 3 days at room temperature in the presence of air. Detection limits were 0.08% by mass SO32- and 0.1% by mass SO42- for 0.1 g fly ash extracted with 100 ml of the EDTA reagent.
Keywords:
CFB ash, cogeneration, fly ash, ion chromatography, sulfate, sulfite
Paper ID: JAI13055
DOI: 10.1520/JAI13055
ASTM International is a member of CrossRef.
Author Cowen, WF Affiliation Chemicals Environmental Technology Center, Air Products and Chemicals, Inc., Allentown, PA
Title: Simple Extraction of Sulfite and Sulfate in Cogeneration Plant Circulating Fluidized Bed Fly Ash for Ion Chromatographic Analysis
Symposium: ,
0-0-0
Committee: on
|