Work Item
ASTM WK68489
New Test Method for Conducting Atmospheric Pressure Carbon Steel Rotating Cylinder Electrode in 3.5 NaCl Solution Saturated with Carbon Dioxide
1. Scope
1.1.This test method covers a generally accepted procedure to conduct the carbon steel rotating cylinder electrode (RCE) experiment in 3.5% NaCl Solution Saturated with Carbon Dioxide at atmospheric pressure and room temperatureKeywords
RCE, rotating cylinder electrode, corrosion inhibitor evaluationRationale
Inhibitor suppliers require to publish the efficiency of their inhibitors in reference to a bench mark. Only then the merits of various corrosion inhibitors (with respect to reducing corrosion) can be evaluated on a common ground. It is important to evaluate the corrosion inhibitors in independent third-party laboratories. The ability and qualification of the third-party laboratories should be evaluated by making them to routinely carry out tests under standard operating conditions and by comparing their test results with Standard Test method results. This Standard Test Method is envisaged to address the above two requirements.
Work Item Status
Date Initiated: 05-31-2019
Technical Contact: Sankara Papavinasam
Item: 000
Ballot:
Status: