Work Item
ASTM WK90030
Revision of C94/C94M-24 Standard Specification for Ready-Mixed Concrete
Rationale
Load cells used in calibrating batch plant scales are rated for operation at a stated temperature range. The ambient temperature at the time of calibration must be within the operational temperature range of the load cell. Report the ambient temperature and the designated high and low temperature range of the load cell.
Work Item Status
Date Initiated: 03-19-2024
Technical Contact: Charles Lambert
Item: 006
Ballot: C09 (25-02)
Status: In Balloting