Work Item
ASTM WK92249
Revision of C991-23 Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings
Rationale
Modify section 6.1.6.1 by removing the reference to the corrosion test method in C665 and replace with reference to C1936 to better align with the balloted changes to C665. C1936 was developed with the intension of replacing the method referenced in C665. Add C1936 to referenced documents Remove Note 3 regarding C1617 which is no longer applicable.
Work Item Status
Date Initiated: 09-10-2024
Technical Contact: Michael Smith
Item: 011
Ballot: C16 (25-01)
Status: In Balloting