Revision of A234/A234M-24 Standard Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Moderate and High Temperature Service

Rationale

Section 7.6 is open to confusion about marking MT. Current sequencing at END of section has been interpreted as (only) mark MT/PT after the removal of any crack & repeat NDE (hence if no repair then no mark). Furthermore, our industry does not want an actual crack “treated” (weld repaired) and then sold. Many MTRs have to state, “No Weld Repair”.

Details

Developed by Subcommittee: A01.22

Committee: A01

Staff Manager: W Scott Orthey

Work Item Status

Date Initiated: 11-19-2024

Technical Contact: Carl Peacock

Item: 004

Ballot: A01.22 (25-01)

Status: Negative Votes Need Resolution