Subcommittee E06.21 on Serviceability
Matching Standards Under the Jurisdiction of E06.21 by Status
- E154/E154M-08a(2025) Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls, or as Ground Cover
- -See also WK92572 proposed Reapproval
- E605/E605M-19(2023) Standard Test Methods for Thickness and Density of Sprayed Fire-Resistive Material (SFRM) Applied to Structural Members
- -See also WK93335 proposed Revision
- E736/E736M-19(2023) Standard Test Method for Cohesion/Adhesion of Sprayed Fire-Resistive Materials Applied to Structural Members
- -See also WK92970 proposed Revision
- E759/E759M-92(2023) Standard Test Method for Effect of Deflection on Sprayed Fire-Resistive Material Applied to Structural Members
- E760/E760M-92(2023) Standard Test Method for Effect of Impact on Bonding of Sprayed Fire-Resistive Material Applied to Structural Members
- E761/E761M-92(2023) Standard Test Method for Compressive Strength of Sprayed Fire-Resistive Material Applied to Structural Members
- E859/E859M-23 Standard Test Method for Air Erosion of Sprayed Fire-Resistive Materials (SFRMs) Applied to Structural Members
- -See also WK84698 proposed Reapproval
- E937/E937M-93(2023) Standard Test Method for Corrosion of Steel by Sprayed Fire-Resistive Material (SFRM) Applied to Structural Members
- E1155/E1155M-23 Standard Test Method for Determining
F Floor Flatness andF F Floor Levelness NumbersL - E1399/E1399M-97(2022) Standard Test Method for Cyclic Movement and Measuring the Minimum and Maximum Joint Widths of Architectural Joint Systems
- E1486-14(2022) Standard Test Method for Determining Floor Tolerances Using Waviness, Wheel Path and Levelness Criteria
- E1486M-14(2022) Standard Test Method for Determining Floor Tolerances Using Waviness, Wheel Path and Levelness Criteria (Metric)
- E1513/E1513M-93(2023) Standard Practice for Application of Sprayed Fire-Resistive Materials (SFRMs)
- E1612/E1612M-94(2022) Standard Specification for Preformed Architectural Compression Seals for Buildings and Parking Structures
- E1643-24 Standard Practice for Selection, Design, Installation, and Inspection of Water Vapor Retarders Used in Contact with Earth or Granular Fill Under Concrete Slabs
- E1745-17(2023) Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs
- -See also WK56708 proposed Revision
- E1783/E1783M-24 Standard Specification for Preformed Architectural Strip Seals for Buildings and Parking Structures
- -See also WK82107 proposed Reapproval
- E1993/E1993M-98(2020) Standard Specification for Bituminous Water Vapor Retarders Used in Contact with Soil or Granular Fill Under Concrete Slabs
- E2174-24 Standard Practice for On-Site Inspection of Installed Firestop Systems
- -See also WK90934 proposed Revision
- -See also WK84733 proposed Revision
- E2393-24 Standard Practice for On-Site Inspection of Installed Fire Resistive Joint Systems and Perimeter Fire Barriers
- -See also WK84734 proposed Revision
- E2634-18(2022) Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems
- E2785-14(2022) Standard Test Method for Exposure of Firestop Materials to Severe Environmental Conditions
- E2786-24 Standard Test Methods for Measuring Expansion of Intumescent Materials Used in Firestop and Joint Systems
- -See also WK88266 proposed Revision
- E2923-24 Standard Practice for Longevity Assessment of Firestop Materials Using Differential Scanning Calorimetry
- -See also WK88267 proposed Revision
- E2924-14(2020) Standard Practice for Intumescent Coatings
- E3037-20 Standard Test Method for Measuring Relative Movement Capabilities of Through-Penetration Firestop Systems
- E3157-23 Standard Guide for Understanding and Using Information Related to Installation of Firestop Systems
- -See also WK91874 proposed Revision
- E3385-24 Standard Practice for On-Site Inspection of Fire Resistive Duct Systems
- E3038-22a Standard Practice for Assessing and Qualifying Candidates as Inspectors of Firestop Systems and Fire-Resistive Joint Systems
- -See also WK65007 proposed Revision
- WK70508 MgO ceramic-cement board, uses, applications, types and sizes
- WK63286 Standard Methods for Testing, Limits, Uses, and Requirements of Magnesium Oxide Cementitious Board Products.
- WK70807 the On-Site Inspection of Installed Board and Wrap Type Fireproofing
- WK70851 Standard Practice for the On-Site Inspection of Installed Spray-Applied Fire Resistive Materials
- WK70416 On-Site Identification of Penetration Firestop Systems and Fire-Resistive Joint Systems and Perimeter Fire Barriers
- WK70852 the On-Site Inspection of Installed Intumescent Fire Resistive Materials
- WK70461 PURITY OF MAGNESIUM OXIDE
- WK61472 Magnesium Oxide Fibre-Mat Reinforced Cementitious Board Products
- WK81370 Determining the Loss-on-Ignition of Light-Burnt Magnesium Oxide.
- WK81405 Determining the Free-Lime Content of Light-Burnt Magnesium Oxide
- WK81406 Determining the Citric Acid Activity of Light-Burnt Magnesium Oxide
- WK92155 Determining the Free Chloride of Magnesium Oxide Panels
- E835/E835M-93(2002) Standard Guide for Modular Coordination of Clay and Concrete Masonry Units (Withdrawn 2011)
- E577-85(2002) Standard Guide for Dimensional Coordination of Rectilinear Building Parts and Systems (Withdrawn 2011)
- E713-88(2002) Standard Guide for Selection of Scales for Metric Building Drawings (Withdrawn 2010)
- E1155M-14 Standard Test Method for Determining
F Floor Flatness andF F Floor Levelness Numbers (Metric) (Withdrawn 2023)L - E621-94(1999)e1 Standard Practice for the Use of Metric (SI) Units in Building Design and Construction (Committee E-6 Supplement to E380) (Withdrawn 2008)